From S.H.O.
|
|
Line 6: |
Line 6: |
| |valign=top| | | |valign=top| |
| {| class="wikitable" style="float:left" | | {| class="wikitable" style="float:left" |
− | |+ Coil 1 | + | |+ <big>Coil 1</big> |
| |- | | |- |
| !width=240| Wire type (e.g. magnet wire) | | !width=240| Wire type (e.g. magnet wire) |
Line 30: |
Line 30: |
| |} | | |} |
| {| class="wikitable" | | {| class="wikitable" |
− | |+ Coil 2 | + | |+ <big>Coil 2</big> |
| |- | | |- |
| !width=240| Wire type (e.g. magnet wire) | | !width=240| Wire type (e.g. magnet wire) |
Line 56: |
Line 56: |
| |valign=top| | | |valign=top| |
| {| class="wikitable" style="float: left;" | | {| class="wikitable" style="float: left;" |
− | |+ Magnets (Group 1) | + | |+ <big>Magnets (Group 1)</big> |
| |- | | |- |
| !width=240| Magnet material (e.g. NdBFe) | | !width=240| Magnet material (e.g. NdBFe) |
Line 77: |
Line 77: |
| |} | | |} |
| {| class="wikitable" style="float: left;" | | {| class="wikitable" style="float: left;" |
− | |+ Magnets (Group 2) | + | |+ <big>Magnets (Group 2)</big> |
| |- | | |- |
| !width=240| Magnet material (e.g. NdBFe) | | !width=240| Magnet material (e.g. NdBFe) |
Line 100: |
Line 100: |
| |valign=top| | | |valign=top| |
| {| class="wikitable" style="float:left" | | {| class="wikitable" style="float:left" |
− | |+ Shaft | + | |+ <big>Shaft</big> |
| |- | | |- |
| !width=240| Length (e.g. 12") | | !width=240| Length (e.g. 12") |
Line 118: |
Line 118: |
| |} | | |} |
| {| class="wikitable" | | {| class="wikitable" |
− | |+ Fan | + | |+ <big>Fan</big> |
| |- | | |- |
| !width=240| Diameter (12") | | !width=240| Diameter (12") |
Revision as of 09:27, 25 April 2016
Parts Dimensions
Coil 1
Wire type (e.g. magnet wire)
|
|
Wire gauge (e.g. 12 AWG)
|
|
Wire length (e.g. 30 meters)
|
|
Wire resistance (e.g. 0.3 ohms)
|
|
Wire insulation (e.g. teflon)
|
|
Rated temperature (e.g. 155 °C)
|
|
Number of turns (e.g. 22 turns)
|
|
Coil 2
Wire type (e.g. magnet wire)
|
|
Wire gauge (e.g. 12 AWG)
|
|
Wire length (e.g. 30 meters)
|
|
Wire resistance (e.g. 0.3 ohms)
|
|
Wire insulation (e.g. teflon)
|
|
Rated temperature (e.g. 155 °C)
|
|
Number of turns (e.g. 22 turns)
|
|
|
Magnets (Group 1)
Magnet material (e.g. NdBFe)
|
|
Magnet grade (e.g. N52)
|
|
Pole width 1 (if rectangular)
|
|
Pole width 2 (if rectangular)
|
|
Pole diameter (if circular)
|
|
Length along magnetization
|
|
Magnets (Group 2)
Magnet material (e.g. NdBFe)
|
|
Magnet grade (e.g. N52)
|
|
Pole width 1 (if rectangular)
|
|
Pole width 2 (if rectangular)
|
|
Pole diameter (if circular)
|
|
Length along magnetization
|
|
|
Shaft
Length (e.g. 12")
|
|
Diameter (e.g. 5/8")
|
|
Alloy (e.g. stainless steel)
|
|
Threaded (Y or N)
|
|
Thread Pitch (e.g. 11 TPI)
|
|
Fan
Diameter (12")
|
|
Blade Pitch (e.g. 2-1/4")
|
|
Number of Blades (e.g. 5)
|
|
Material (e.g. Stainless steel)
|
|
Typical use (e.g. Automotive)
|
|
|
Operating characteristics
Pre-run testing on ___ /___ / 20___
Rotational speed □ Tachometer used
|
Induced AC voltage □ Root mean square
|
0 RPS = 0 RPM
|
|
1 RPS = 60 RPM
|
|
2 RPS = 120 RPM
|
|
3 RPS = 180 RPM
|
|
4 RPS = 240 RPM
|
|
5 RPS = 300 RPM
|
|
6 RPS = 360 RPM
|
|
7 RPS = 420 RPM
|
|
8 RPS = 480 RPM
|
|
9 RPS = 540 RPM
|
|
10 RPS = 600 RPM
|
|
____ RPS = ______ RPM
|
|
____ RPS = ______ RPM
|
|
____ RPS = ______ RPM
|
|
____ RPS = ______ RPM
|
|
Test run on ___ /___ / 20___
Time HH:MM AM/PM
|
Current Amps
|
Rotation Speed RPM
|
Air speed □ __/ s □ __/ h
|
Air Temps. (4 Max) □ °C □ °F
|
Coil Temps. (2 per coil) □ °C □ °F
|
____:____ __M
|
Not running
|
Not running
|
Not running
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
Not running
|
Not running
|
Not running
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
|
|
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
Not running
|
Not running
|
Not running
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
____:____ __M
|
Not running
|
Not running
|
Not running
|
_____ _____ _____ _____
|
_____ _____ | _____ _____
|
|
Site map
HQ ● Glossary ● April 2016 Presentation