Difference between revisions of "Data collection"

From S.H.O.
Jump to: navigation, search
(Parts Dimensions)
Line 8: Line 8:
 
|+ Coil 1
 
|+ Coil 1
 
|-
 
|-
!width=200| Wire type
+
!width=240| Wire type (e.g. magnet wire)
|width=200|  
+
|width=240|  
 
|-
 
|-
! Rated temperature
+
! Wire gauge (e.g. 12 AWG)
|  
+
|
 
|-
 
|-
! Coil gauge
+
! Wire length (e.g. 30 meters)
 
|
 
|
 
|-
 
|-
! Wire length
+
! Wire resistance (e.g. 0.3 ohms)
 
|
 
|
 
|-
 
|-
! Number of turns
+
! Wire insulation (e.g. teflon)
 
|
 
|
 
|-
 
|-
! Resistance
+
! Rated temperature (e.g. 155 °C)
 +
|
 +
|-
 +
! Number of turns (e.g. 22 turns)
 
|
 
|
 
|}
 
|}
Line 29: Line 32:
 
|+ Coil 2
 
|+ Coil 2
 
|-
 
|-
!width=200| Wire type
+
!width=240| Wire type (e.g. magnet wire)
|width=200|  
+
|width=240|  
 
|-
 
|-
! Rated temperature
+
! Wire gauge (e.g. 12 AWG)
|  
+
|
 
|-
 
|-
! Coil gauge
+
! Wire length (e.g. 30 meters)
 
|
 
|
 
|-
 
|-
! Wire length
+
! Wire resistance (e.g. 0.3 ohms)
 
|
 
|
 
|-
 
|-
! Number of turns
+
! Wire insulation (e.g. teflon)
 
|
 
|
 
|-
 
|-
! Resistance
+
! Rated temperature (e.g. 155 °C)
 +
|
 +
|-
 +
! Number of turns (e.g. 22 turns)
 
|
 
|
 
|}
 
|}
Line 52: Line 58:
 
|+ Magnets (Group 1)
 
|+ Magnets (Group 1)
 
|-
 
|-
!width=200| Magnet material
+
!width=240| Magnet material (e.g. NdBFe)
|width=200|  
+
|width=240|  
 
|-
 
|-
! Magnet grade
+
! Magnet grade (e.g. N52)
 
|  
 
|  
 
|-
 
|-
Line 73: Line 79:
 
|+ Magnets (Group 2)
 
|+ Magnets (Group 2)
 
|-
 
|-
!width=200| Magnet material
+
!width=240| Magnet material (e.g. NdBFe)
|width=200|  
+
|width=240|  
 
|-
 
|-
! Magnet grade
+
! Magnet grade (e.g. N52)
 
|  
 
|  
 
|-
 
|-
Line 96: Line 102:
 
|+ Shaft
 
|+ Shaft
 
|-
 
|-
!width=200| Length
+
!width=240| Length (e.g. 12")
|width=200|  
+
|width=240|  
 
|-
 
|-
! Diameter
+
! Diameter (e.g. 5/8")
 
|
 
|
 
|-
 
|-
! Alloy
+
! Alloy (e.g. stainless steel)
 
|
 
|
 
|-
 
|-
Line 108: Line 114:
 
|
 
|
 
|-
 
|-
! Thread Pitch
+
! Thread Pitch (e.g. 11 TPI)
 
|
 
|
 
|}
 
|}
Line 114: Line 120:
 
|+ Fan
 
|+ Fan
 
|-
 
|-
!width=200| Diameter
+
!width=240| Diameter (12")
|width=200|  
+
|width=240|  
 
|-
 
|-
! Blade Pitch
+
! Blade Pitch (e.g. 2-1/4")
 
|
 
|
 
|-
 
|-
! Number of Blades
+
! Number of Blades (e.g. 5)
 
|
 
|
 
|-
 
|-
! Material
+
! Material (e.g. Stainless steel)
 
|
 
|
 
|-
 
|-
! Typical use
+
! Typical use (e.g. Automotive)
 
|
 
|
 
|}
 
|}

Revision as of 09:23, 25 April 2016

Parts Dimensions

Coil 1
Wire type (e.g. magnet wire)
Wire gauge (e.g. 12 AWG)
Wire length (e.g. 30 meters)
Wire resistance (e.g. 0.3 ohms)
Wire insulation (e.g. teflon)
Rated temperature (e.g. 155 °C)
Number of turns (e.g. 22 turns)
Coil 2
Wire type (e.g. magnet wire)
Wire gauge (e.g. 12 AWG)
Wire length (e.g. 30 meters)
Wire resistance (e.g. 0.3 ohms)
Wire insulation (e.g. teflon)
Rated temperature (e.g. 155 °C)
Number of turns (e.g. 22 turns)
Magnets (Group 1)
Magnet material (e.g. NdBFe)
Magnet grade (e.g. N52)
Pole width 1 (if rectangular)
Pole width 2 (if rectangular)
Pole diameter (if circular)
Length along magnetization
Magnets (Group 2)
Magnet material (e.g. NdBFe)
Magnet grade (e.g. N52)
Pole width 1 (if rectangular)
Pole width 2 (if rectangular)
Pole diameter (if circular)
Length along magnetization
Shaft
Length (e.g. 12")
Diameter (e.g. 5/8")
Alloy (e.g. stainless steel)
Threaded (Y or N)
Thread Pitch (e.g. 11 TPI)
Fan
Diameter (12")
Blade Pitch (e.g. 2-1/4")
Number of Blades (e.g. 5)
Material (e.g. Stainless steel)
Typical use (e.g. Automotive)

Operating characteristics

Pre-run testing on ___ /___ / 20___

Rotational speed
□ Tachometer used

Induced AC voltage
□ Root mean square
0 RPS = 0 RPM
1 RPS = 60 RPM
2 RPS = 120 RPM
3 RPS = 180 RPM
4 RPS = 240 RPM
5 RPS = 300 RPM
6 RPS = 360 RPM
7 RPS = 420 RPM
8 RPS = 480 RPM
9 RPS = 540 RPM
10 RPS = 600 RPM
____ RPS = ______ RPM
____ RPS = ______ RPM
____ RPS = ______ RPM
____ RPS = ______ RPM
Test run on ___ /___ / 20___

Time
HH:MM AM/PM

Current
Amps

Rotation Speed
RPM

Air speed
□ __/ s □ __/ h

Air Temps. (4 Max)
□ °C □ °F

Coil Temps. (2 per coil)
□ °C □ °F
____:____ __M Not running Not running Not running _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M Not running Not running Not running _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M Not running Not running Not running _____ _____ _____ _____ _____ _____ | _____ _____
____:____ __M Not running Not running Not running _____ _____ _____ _____ _____ _____ | _____ _____

Site map

HQGlossaryApril 2016 Presentation